| Test ID | Category | Test | Subject | Value | Target | Date | Analyst | Result |
|---|---|---|---|---|---|---|---|---|
| T-8821 | Mechanical | Compression ASTM D143 | BAT-24-0418-01 batch | 54.6 MPa | ≥ 50 MPa | 2026-04-18 | R. Chen | Pass |
| T-8820 | Environmental | Water absorption (24h) ASTM D570 | BAT-24-0418-01 batch | 2.9 % | ≤ 4 % | 2026-04-18 | R. Chen | Pass |
| T-8819 | Environmental | UV (500h QUV) ASTM G154 | BAT-24-0418-01 batch | 9.7 / 10 | ≥ 8.5 | 2026-04-18 | R. Chen | Pass |
| T-8818 | Fire | Flame spread index ASTM E84 | WS-INS-02 recipe | Class C | Class B+ | 2026-04-17 | J. Park | Fail |
| T-8817 | Acoustic | STC rating ASTM E90 | WS-ACS-02 recipe | 60 | ≥ 55 | 2026-04-15 | M. Torres | Pass |
| T-8816 | Fire | Flame spread index ASTM E84 | WS-FAC-01 recipe | Class B | Class B+ | 2026-04-12 | R. Chen | Pass |
| T-8815 | Thermal | Thermal conductivity ASTM C518 | WS-INS-01 recipe | 0.036 W/m·K | ≤ 0.040 | 2026-04-10 | J. Park | Pass |
| T-8814 | Mechanical | Flexural strength ASTM D790 | WS-FUR-01 recipe | inconclusive | ≥ 18 MPa | 2026-04-09 | R. Chen | Inconclusive |